HVAC & Airflow

Blower Door CFM50 Calculator

Building leakage flow at a 50 Pascal test pressure.

Enter your values

ⓘ Live results

Results
ACH50
6
Natural ACH (n-factor 20)
0.3
Effective leakage rate
100 CFM50 per 1000 cu ft

Quick answer

ACH50 equals CFM50 times 60, divided by the building's conditioned volume.

ACH50 = CFM50 x 60 / Volume

How to use the Blower Door CFM50 Calculator

  1. 1Run a blower door test and record the CFM50 fan flow reading.
  2. 2Enter the building's conditioned volume.
  3. 3Read ACH50, the standard airtightness metric used for code compliance.

Worked example

Using the values the calculator loads with:

Inputs

  • Blower door CFM50 reading1800 CFM
  • Conditioned volume18000 cu ft

Results

  • ACH506
  • Natural ACH (n-factor 20)0.3
  • Effective leakage rate100 CFM50 per 1000 cu ft

Frequently asked questions

What ACH50 is considered tight?

Modern high-performance homes often target 1.0-3.0 ACH50; older leaky homes can exceed 10-15.

What is the n-factor?

It converts test-pressure ACH50 to natural infiltration ACH; 20 is a common simplified assumption, varying with climate and building height.