HVAC & Airflow

Range Hood CFM Calculator

Kitchen hood size by cooktop width and type.

Enter your values

ⓘ Live results

Results
Recommended hood
600 CFM
By cooktop width
300 CFM
By burner BTU
600 CFM
Minimum hood width
39 in
Make-up air needed?
Yes — most codes require make-up air above 400 CFM

Quick answer

Wall hoods need roughly 100 CFM per linear foot of cooktop for electric and 100 CFM per 10,000 BTU for gas; island hoods need about 50% more.

CFM = cooktop width (ft) x 100 x island factor

How to use the Range Hood CFM Calculator

  1. 1Measure the cooktop width in inches.
  2. 2Pick the fuel type and, for gas, add up the burner BTU ratings.
  3. 3Choose wall or island — island hoods lose air on all four sides.

Worked example

Using the values the calculator loads with:

Inputs

  • Cooktop width36 in
  • FuelGas
  • Total burner BTU (gas)60000 BTU/h
  • Hood positionAgainst wall

Results

  • Recommended hood600 CFM
  • By cooktop width300 CFM
  • By burner BTU600 CFM
  • Minimum hood width39 in
  • Make-up air needed?Yes — most codes require make-up air above 400 CFM

Frequently asked questions

Is 600 CFM too much?

It is fine for a big gas range, but above 400 CFM most codes require a make-up air supply to avoid back-drafting appliances.

Does duct size matter?

Yes — a 600 CFM hood on 6 inch duct will never reach its rating; use 8 or 10 inch.

About this calculator

Results are estimates for general information. For medical, legal, structural or financial decisions, confirm with a qualified professional.