Roof Ventilation Calculator
Net free area for intake and exhaust vents.
Reviewed by James Whitfield · How we check our maths
Your values
ⓘ Live results
Results
- Total net free area
- 5 sq ft (720 sq in)
- Intake (soffit) area
- 360 sq in
- Exhaust (ridge) area
- 360 sq in
- Soffit vents needed
- 14 at 26 sq in each
- Ridge vent length
- 20 ft at 18 sq in per ft
Quick answer
Attics need 1 square foot of net free vent area per 150 square feet of attic floor, or per 300 with a vapour barrier and balanced venting.
The formula
NFA = attic area / ratio, split 50/50 intake and exhaust
Worked example
Worked example
Using the values the calculator loads with.
Inputs
- Attic floor area1500 sq ft
- Code rule1:300 (balanced with barrier)
Result
- Total net free area5 sq ft (720 sq in)
- Intake (soffit) area360 sq in
- Exhaust (ridge) area360 sq in
- Soffit vents needed14 at 26 sq in each
- Ridge vent length20 ft at 18 sq in per ft
How to use the Roof Ventilation Calculator
- 1Enter the attic floor area in square feet.
- 2Choose 1:300 if you have a vapour barrier and balanced vents, otherwise 1:150.
- 3Split the area roughly evenly between low intake and high exhaust.
Frequently asked questions
Why split intake and exhaust?
Air must enter low and leave high; exhaust-only venting pulls conditioned air out of the house instead.
Does vent net free area equal vent size?
No — louvres and screens block much of the opening, so use the manufacturer's NFA rating.