HVAC & Airflow

Supply/Return Ratio Calculator

Check supply-to-return airflow balance.

Enter your values

ⓘ Live results

Results
Supply/return ratio
0.89
Airflow imbalance
150 CFM
Status
Return-starved — building will pressurize

Quick answer

A well-balanced duct system keeps return airflow within about 10% of total supply airflow to avoid pressurizing or depressurizing the building.

Ratio = return CFM / supply CFM

How to use the Supply/Return Ratio Calculator

  1. 1Total the supply CFM across every register.
  2. 2Total the return CFM across every return grille.
  3. 3Compare the ratio to the 0.9-1.1 balanced range; add return path capacity if it falls outside.

Worked example

Using the values the calculator loads with:

Inputs

  • Total supply CFM1400 CFM
  • Total return CFM1250 CFM

Results

  • Supply/return ratio0.89
  • Airflow imbalance150 CFM
  • StatusReturn-starved — building will pressurize

Frequently asked questions

Why does imbalance matter?

A pressurized house pushes conditioned air out through gaps, while a depressurized one pulls unconditioned or combustion air in.

What's a quick fix for return-starved systems?

Add return grilles or transfer ducts in closed-door rooms before adding more supply capacity.