Animal Shelter Ventilation Calculator

Air changes per hour for an animal shelter housing area.

Enter your values

ⓘ Live results

Results
Required outdoor air
1,200 CFM
Volume
6,000 cu ft
No recirculation between wards
Recommended to prevent cross-ward disease spread
Humidity target
30-70% RH to limit pathogen survival

Quick answer

Animal shelter housing areas are commonly ventilated at 10-15 outdoor air changes per hour to reduce airborne disease transmission and control odour, per shelter design guidelines.

CFM = volume x ACH / 60

How to use the Animal Shelter Ventilation Calculator

  1. 1Enter housing area and ceiling height.
  2. 2Use 10-15 ACH per shelter medicine guidelines.
  3. 3Avoid recirculating air between disease-risk wards; use dedicated exhaust per ward where possible.

Worked example

Using the values the calculator loads with:

Inputs

  • Housing area600 sq ft
  • Ceiling height10 ft
  • Air changes12 ACH

Results

  • Required outdoor air1,200 CFM
  • Volume6,000 cu ft
  • No recirculation between wardsRecommended to prevent cross-ward disease spread
  • Humidity target30-70% RH to limit pathogen survival

Frequently asked questions

Why so much outdoor air compared to a home?

High animal density and disease risk (e.g. kennel cough, parvovirus) call for aggressive dilution ventilation, much higher than residential rates.

Can HVAC recirculate shelter-wide?

Best practice isolates airflow by ward so an outbreak in one area is not spread through shared return ductwork.