Make-Up Air CFM Calculator
Replacement air for powerful exhaust fans.
Reviewed by James Whitfield · How we check our maths
Your values
ⓘ Live results
Results
- Make-up air required
- 800 CFM
- Duct free area
- 230 sq in
- Round duct diameter
- 17.1 in
- Heating load of that air at 50 °F rise
- 43,200 BTU/h
Quick answer
Make-up air should replace roughly 80–100% of the exhausted air once natural infiltration is accounted for.
The formula
make-up CFM = exhaust CFM − natural infiltration
Worked example
Worked example
Using the values the calculator loads with.
Inputs
- Total exhaust900 CFM
- Natural infiltration allowance100 CFM
- Duct velocity for make-up500 FPM
Result
- Make-up air required800 CFM
- Duct free area230 sq in
- Round duct diameter17.1 in
- Heating load of that air at 50 °F rise43,200 BTU/h
How to use the Make-Up Air CFM Calculator
- 1Add up every exhaust device that can run at once — hood, bath fans, dryer.
- 2Subtract a small natural infiltration allowance for leaky homes.
- 3Size a powered or passive make-up air path for the balance.
Frequently asked questions
What happens without make-up air?
The house goes negative, doors get hard to open and combustion appliances can back-draft carbon monoxide.
Does make-up air need heating?
In cold climates yes, otherwise you dump freezing air into the kitchen every time the hood runs.