Supply Air Temperature Rise Calculator

Furnace temperature rise from CFM and BTU.

Enter your values

ⓘ Live results

Results
Temperature rise
52.9 °F
Assessment
Within typical rated range

Quick answer

Temperature rise across a furnace equals its heat output divided by 1.08 times the system airflow in CFM.

ΔT = BTU/hr output / (1.08 x CFM)

How to use the Supply Air Temperature Rise Calculator

  1. 1Enter the furnace's rated heating output in BTU per hour.
  2. 2Enter the system's actual airflow in CFM at the current blower speed.
  3. 3Compare the resulting temperature rise to the furnace nameplate's rated rise range.

Worked example

Using the values the calculator loads with:

Inputs

  • Furnace output80000 BTU/hr
  • System airflow1400 CFM

Results

  • Temperature rise52.9 °F
  • AssessmentWithin typical rated range

Frequently asked questions

Why does temperature rise matter?

Running outside the furnace's rated rise range risks overheating the heat exchanger or delivering lukewarm air.

How do I fix a high rise?

Check for a dirty filter, closed dampers or undersized ducts restricting airflow, or increase blower speed.