HVAC & Airflow

Workshop Exhaust Fan Calculator

General exhaust airflow for a home workshop.

Enter your values

ⓘ Live results

Results
Required exhaust
768 CFM
Shop volume
5,760 cu ft
Fan at 6 in duct, 1200 FPM
3911 FPM check
Intake louvre area at 500 FPM
1.54 sq ft

Quick answer

Workshops are generally ventilated at 6-10 air changes per hour for general fume and dust dilution, more for solvent-heavy or welding work.

CFM = volume x ACH / 60

How to use the Workshop Exhaust Fan Calculator

  1. 1Calculate the workshop volume from its dimensions.
  2. 2Choose an air-change rate based on the work being done — higher for painting or welding.
  3. 3Size a matching fresh air intake so the fan is not starved.

Worked example

Using the values the calculator loads with:

Inputs

  • Shop length24 ft
  • Shop width24 ft
  • Ceiling height10 ft
  • Air changes8 ACH

Results

  • Required exhaust768 CFM
  • Shop volume5,760 cu ft
  • Fan at 6 in duct, 1200 FPM3911 FPM check
  • Intake louvre area at 500 FPM1.54 sq ft

Frequently asked questions

Do I need spot extraction too?

Yes for welding, sanding or solvent use — general exhaust dilutes background fumes but does not replace source capture.

Can a box fan in a window work?

For light hobby use yes, but it will not meet the ACH target of a properly ducted exhaust fan.