Ridge Vent Airflow Calculator

Passive exhaust airflow through a ridge vent by stack effect.

Enter your values

ⓘ Live results

Results
Estimated passive airflow
1,138 CFM
Net free area used
2 sq ft
Note
Actual airflow also depends on wind, which typically dominates over stack effect
Balance check
Soffit intake NFA should equal or exceed ridge NFA

Quick answer

Ridge vent airflow depends on net free area and the stack effect from attic-to-outside temperature difference; well-designed systems commonly move several hundred CFM passively in warm attics.

CFM ~ NFA(sq ft) x C x sqrt(height x deltaT)

How to use the Ridge Vent Airflow Calculator

  1. 1Get the ridge vent's rated net free area (from the product data, in sq ft).
  2. 2Enter the vertical separation between ridge and soffit vents.
  3. 3Enter a typical attic-to-outside temperature difference to estimate stack-driven airflow.

Worked example

Using the values the calculator loads with:

Inputs

  • Ridge vent net free area2 sq ft
  • Vertical vent separation (ridge to soffit)10 ft
  • Attic-to-outside temp diff25 °F

Results

  • Estimated passive airflow1,138 CFM
  • Net free area used2 sq ft
  • NoteActual airflow also depends on wind, which typically dominates over stack effect
  • Balance checkSoffit intake NFA should equal or exceed ridge NFA

Frequently asked questions

Does wind matter more than stack effect?

Often yes — ridge vents are primarily wind-driven, with stack effect providing a baseline even in calm conditions.

What if soffit intake is undersized?

The ridge vent will starve for makeup air and airflow drops sharply — balance soffit and ridge NFA 1:1.